Open Access
Numéro
Volume 5, 2015
38th World Congress of Vine and Wine (Part 2)
Numéro d'article 06001
Nombre de pages 5
Section Oenology
DOI https://doi.org/10.1051/oivconf/201506001
Publié en ligne 12 août 2015
  • S . Bodenschatz, Kompaktwissen Desinfektion: Neuauflage des Standardwerks, Handbuch für den Desinfektor, Behr‘s Verlag (2005) [Google Scholar]
  • K. Carrick., M. Barney, A. Navarro, D. Ryder, The comparison of four bioluminometer and their swab kits for instant hygiene monitoring and detection of microorganisms in the brewery, Journal of Institute of Brewing, 107, Nr. 1 (2001) [Google Scholar]
  • N.B , Hallam, J.R. West, C.F. Forster, J. Simms, The potential for biofilm growth in water distribution systems, water Res. 35, 17, 4063–4071 (2001) [CrossRef] [PubMed] [Google Scholar]
  • F. Hammes, M. Berney, Y. Wang, M. Vital, O. Köster and T. Egli, Flow- Cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes, water Res., 42 (1–2), 269–277 (2008) [CrossRef] [Google Scholar]
  • A. Kramer, I. Schwebke und G. Kampf, How long do nosocomial pathogens persit on inanimate surfaces? A systematic review BMC Infectious Diseaeses, 6, 130 (2006) [Google Scholar]
  • A. Kerneys, F. Nakache, A. Deguin, M. Feinberg,. The effects of water residence time on the biological quality in a distribution network. Water Res. 29, 1719–1727 (1995) [CrossRef] [Google Scholar]
  • K. Lautenschlager, N. Boon, Y. Wang, T. Egli., F. Hammes, Overnight stagnation of drinking water in household taps induces microbial growth and changes in community composition Water Research 44, 2010, 4868–4877 [Google Scholar]
  • P. Niquette, P. Servais, R. Savoir,. Impact of pipe materials on densities of fixed bacterial biomass in a drinking water distribution system. Water Res. 34, 1952–1956 (2000) [CrossRef] [Google Scholar]
  • J.M. Rinta – Kanto, M.J. Lehtola, T. Vartianinen and P.J. Martikainen. Rapid enumeration of virus – like particles in drinking water samples using SYBR green I-Staining, Water Res., 38, 2614–2618 (2004) [CrossRef] [Google Scholar]
  • D.P. Satory, Heterotrophic plate count monitoring of treated drinking water in the UK, a useful operation tool, Int. J. Food Microbiol., 92, 297–306 (2004) [CrossRef] [Google Scholar]
  • P. Servais, G. Billen, P. Laurent, Y. Levi, G. Randon, Studies of BDOC and bacterial dynamics in the drinking water distribution system of the Northern Parisian suburbs. Revue das Sci. de léau 5, 69–89 (1992) [Google Scholar]
  • P. Servais, P. Laurent, G. Randon Comparison of bacterial dynamics in various French distribution systems J. Water Sci. Res. Technol. –Aqua 44, 10–17 (1995) [Google Scholar]
  • E. Siebel, Y. Wang, T. Egli, F. Hammes Correlation between total cell concentration, total adenosine triphosphate concentration and heterotrophic plate counts during microbial monitoring of drinking water, Drinking Engeneering and Science Discussions 1, 71–86 (2008) [Google Scholar]
  • E. Storgårds, K. Tapani, O. Sinebrychoff, P. Hartwall, O. Hartwall, R. Saleva, O. Oyj, M-L. Suihko, J. Microbial Attachment and Biofilm Formation in Brewery Bottling Plants. Am. Soc. Brew. Chem. 64(1), 8–15 (2006) [Google Scholar]
  • M. Timke, Wang-Lieu, K., Altendorfer, A. Lipski, Identity, beer spoiling and biofilm forming potential of yeasts from beer bottling plant associated biofilms, Antonie van Leeuwenhoek 93, 151–161 (2008) [Google Scholar]
  • Trinkwasserverordnung Verordnung des Bundesministers für soziale Sicherheit und Generationen über die Qualität von Wasser für den menschlichen Gebrauch (Trinkwasserverordnung – TWV) StF: BGBl. II Nr. 304/2001 [CELEX-Nr.: 398L0083] (2001) [Google Scholar]
  • C. Ziegelwagner, K. Silhavy-Richter, und K. Mandl, Antimikrobielle Wirkung von Wein Ithakajournal, 1, 47–56 (2012) [Google Scholar]
  • B.P. Zietz, J.D. de Vergara, H. Dunkelberg Copper concentrations in tap water and possible effects on infant‘s health results of a study in Lower Saxony, Germany, Environ. Res. 92, 129–138 (2003) [Google Scholar]
  • B.P Zietz,. J. Lass, R. Suchenwirth Assessment and management of tap water lead concetration in Lower Saxony, Germany. Int. J. Environ. Health Res. 17, 407–418 (2007) [Google Scholar]
  • K. Venkateswaran, N. Hattori, L.D. Myron, R . Kern ATP as a biomarker of viable microorganisms in clean-room facilities Journal of Microbiological Methods 52, 367–377 (2003) [Google Scholar]
  • WHO: World Health Organization, Guide lines for Drinking-water Quality (electronic resource): incorporating first addendum, 1, Recommendations, 3.Ed., (2006) [Google Scholar]