Open Access
Numéro
Volume 5, 2015
38th World Congress of Vine and Wine (Part 2)
Numéro d'article 06001
Nombre de pages 5
Section Oenology
DOI https://doi.org/10.1051/oivconf/20150506001
Publié en ligne 12 août 2015
  • S . Bodenschatz, Kompaktwissen Desinfektion: Neuauflage des Standardwerks, Handbuch für den Desinfektor, Behr‘s Verlag (2005)
  • K. Carrick., M. Barney, A. Navarro, D. Ryder, The comparison of four bioluminometer and their swab kits for instant hygiene monitoring and detection of microorganisms in the brewery, Journal of Institute of Brewing, 107, Nr. 1 (2001) [CrossRef]
  • N.B , Hallam, J.R. West, C.F. Forster, J. Simms, The potential for biofilm growth in water distribution systems, water Res. 35, 17, 4063–4071 (2001) [CrossRef] [PubMed]
  • F. Hammes, M. Berney, Y. Wang, M. Vital, O. Köster and T. Egli, Flow- Cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes, water Res., 42 (1–2), 269–277 (2008) [CrossRef]
  • A. Kramer, I. Schwebke und G. Kampf, How long do nosocomial pathogens persit on inanimate surfaces? A systematic review BMC Infectious Diseaeses, 6, 130 (2006)
  • A. Kerneys, F. Nakache, A. Deguin, M. Feinberg,. The effects of water residence time on the biological quality in a distribution network. Water Res. 29, 1719–1727 (1995) [CrossRef]
  • K. Lautenschlager, N. Boon, Y. Wang, T. Egli., F. Hammes, Overnight stagnation of drinking water in household taps induces microbial growth and changes in community composition Water Research 44, 2010, 4868–4877 [CrossRef]
  • P. Niquette, P. Servais, R. Savoir,. Impact of pipe materials on densities of fixed bacterial biomass in a drinking water distribution system. Water Res. 34, 1952–1956 (2000) [CrossRef]
  • J.M. Rinta – Kanto, M.J. Lehtola, T. Vartianinen and P.J. Martikainen. Rapid enumeration of virus – like particles in drinking water samples using SYBR green I-Staining, Water Res., 38, 2614–2618 (2004) [CrossRef]
  • D.P. Satory, Heterotrophic plate count monitoring of treated drinking water in the UK, a useful operation tool, Int. J. Food Microbiol., 92, 297–306 (2004) [CrossRef]
  • P. Servais, G. Billen, P. Laurent, Y. Levi, G. Randon, Studies of BDOC and bacterial dynamics in the drinking water distribution system of the Northern Parisian suburbs. Revue das Sci. de léau 5, 69–89 (1992)
  • P. Servais, P. Laurent, G. Randon Comparison of bacterial dynamics in various French distribution systems J. Water Sci. Res. Technol. –Aqua 44, 10–17 (1995)
  • E. Siebel, Y. Wang, T. Egli, F. Hammes Correlation between total cell concentration, total adenosine triphosphate concentration and heterotrophic plate counts during microbial monitoring of drinking water, Drinking Engeneering and Science Discussions 1, 71–86 (2008)
  • E. Storgårds, K. Tapani, O. Sinebrychoff, P. Hartwall, O. Hartwall, R. Saleva, O. Oyj, M-L. Suihko, J. Microbial Attachment and Biofilm Formation in Brewery Bottling Plants. Am. Soc. Brew. Chem. 64(1), 8–15 (2006)
  • M. Timke, Wang-Lieu, K., Altendorfer, A. Lipski, Identity, beer spoiling and biofilm forming potential of yeasts from beer bottling plant associated biofilms, Antonie van Leeuwenhoek 93, 151–161 (2008)
  • Trinkwasserverordnung Verordnung des Bundesministers für soziale Sicherheit und Generationen über die Qualität von Wasser für den menschlichen Gebrauch (Trinkwasserverordnung – TWV) StF: BGBl. II Nr. 304/2001 [CELEX-Nr.: 398L0083] (2001)
  • C. Ziegelwagner, K. Silhavy-Richter, und K. Mandl, Antimikrobielle Wirkung von Wein Ithakajournal, 1, 47–56 (2012)
  • B.P. Zietz, J.D. de Vergara, H. Dunkelberg Copper concentrations in tap water and possible effects on infant‘s health results of a study in Lower Saxony, Germany, Environ. Res. 92, 129–138 (2003)
  • B.P Zietz,. J. Lass, R. Suchenwirth Assessment and management of tap water lead concetration in Lower Saxony, Germany. Int. J. Environ. Health Res. 17, 407–418 (2007)
  • K. Venkateswaran, N. Hattori, L.D. Myron, R . Kern ATP as a biomarker of viable microorganisms in clean-room facilities Journal of Microbiological Methods 52, 367–377 (2003)
  • WHO: World Health Organization, Guide lines for Drinking-water Quality (electronic resource): incorporating first addendum, 1, Recommendations, 3.Ed., (2006)

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.